Pratique des Biostatistiques
Dernière modification: 15 décembre 2010

Exercice

  • strict warning: Non-static method view::load() should not be called statically in /home/iamin/www/umdb/biostats/sites/default/modules/views/views.module on line 906.
  • strict warning: Declaration of views_plugin_style_default::options() should be compatible with views_object::options() in /home/iamin/www/umdb/biostats/sites/default/modules/views/plugins/views_plugin_style_default.inc on line 24.
  • strict warning: Declaration of views_plugin_row::options_validate() should be compatible with views_plugin::options_validate(&$form, &$form_state) in /home/iamin/www/umdb/biostats/sites/default/modules/views/plugins/views_plugin_row.inc on line 134.
  • strict warning: Declaration of views_plugin_row::options_submit() should be compatible with views_plugin::options_submit(&$form, &$form_state) in /home/iamin/www/umdb/biostats/sites/default/modules/views/plugins/views_plugin_row.inc on line 134.
  • strict warning: Declaration of views_handler_filter::options_validate() should be compatible with views_handler::options_validate($form, &$form_state) in /home/iamin/www/umdb/biostats/sites/default/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter::options_submit() should be compatible with views_handler::options_submit($form, &$form_state) in /home/iamin/www/umdb/biostats/sites/default/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter_boolean_operator::value_validate() should be compatible with views_handler_filter::value_validate($form, &$form_state) in /home/iamin/www/umdb/biostats/sites/default/modules/views/handlers/views_handler_filter_boolean_operator.inc on line 159.
  • strict warning: Declaration of views_handler_argument::init() should be compatible with views_handler::init(&$view, $options) in /home/iamin/www/umdb/biostats/sites/default/modules/views/handlers/views_handler_argument.inc on line 744.
  • strict warning: Non-static method view::load() should not be called statically in /home/iamin/www/umdb/biostats/sites/default/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home/iamin/www/umdb/biostats/sites/default/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home/iamin/www/umdb/biostats/sites/default/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home/iamin/www/umdb/biostats/sites/default/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home/iamin/www/umdb/biostats/sites/default/modules/views/views.module on line 906.

On analyse la validité du dépistage du cancer de la prostate par dosage de la PSA (prostatic specific antigen). Ce dosage est réalisé chez 15 patients: 9 malades et 6 sains. Les résultats suivants sont obtenus (dosage de la PSA exprimé en ng/ml):

  • malades: 2,7 – 3,0 – 4,0 – 4,6 – 5,4 – 5,5 – 6,4 – 8,2 – 10,1
  • sains: 0,7 – 1,2 – 1,5 – 3,8 – 5,1 – 6,2

Déterminer la validité de ce test de dépistage du cancer de la prostate au moyen du calcul de la surface sous la courbe ROC. Que signifie la valeur obtenue ?